Guides
Which documents do you need for a flat roof?
For a flat roof, you collect the manufacturer's documents for each product. If a product is covered by a harmonised standard, these include the declaration of performance (DoP) and the CE marking. The EPB reporter and the post-intervention file (PID) ask which product you installed exactly. Below is the rule for each document, with its official source.
Checked against the sources on 25/10/2026
01
Which documents do you collect for each product?
A flat roof is made of several products. For each product, collect these documents:
- The declaration of performance (DoP). The manufacturer draws it up when the product is covered by a harmonised standard or has a European Technical Assessment (Article 4(1) of Regulation (EU) No 305/2011). A copy comes with each product, on paper or electronically (Article 7(1)).
- The CE marking. It goes on every product for which the manufacturer drew up a declaration of performance (Article 8(2)). It is on the product or on a label. If that is not possible, it is on the packaging or in the accompanying documents (Article 9(1)).
- The technical data sheet. It describes the product and how to install it. On the essential characteristics, it may only give performance that is also in the declaration of performance (Article 4(2)).
- The technical approval (ATG), if the product has one. According to the BUtgb-UBAtc, an ATG is voluntary: no legal requirement makes it mandatory. It is meant to make the product easier to accept, for example for architects and contractors.
- The EPD (environmental product declaration), if the manufacturer has one. According to the FPS Public Health, all environmental communication about a construction product must be backed by a compliant declaration, the B-EPD (Royal Decree of 22 May 2014).
Since 8 January 2026, Regulation (EU) 2024/3110 applies as well. For a product covered by a harmonised standard under Regulation (EU) No 305/2011, the rules on the declaration of performance and the CE marking keep applying as long as that standard is not withdrawn (Article 95(3) and (8)).
Sources: Regulation (EU) No 305/2011 (Construction Products Regulation), EUR-Lex, BUtgb-UBAtc: applying for a technical approval (ATG), FPS Public Health: environmental product declarations (B-EPD), Regulation (EU) 2024/3110 (new Construction Products Regulation), EUR-Lex
02
Who asks for which document?
This is what the architect, the EPB reporter and the safety and health coordinator need:
- Whoever specifies or chooses the product, such as the architect: the declaration of performance. According to the FPS Economy, it is there to choose a product based on its intended use. An ATG is meant to make acceptance easier for specifiers such as architects.
- The EPB reporter: which insulation product you installed, and how thick it is. With the product name, the reporter looks up the lambda value in the EPB product database. See the EPB question below.
- The safety and health coordinator: the identification of the materials used, for the post-intervention file. If only one contractor works on the site, the client draws up the PID, or someone the client appoints. See the PID question below.
Sources: FPS Economy: the trading of construction products, BUtgb-UBAtc: applying for a technical approval (ATG), Flanders, EPB-pedia: de warmtegeleidbaarheid van een materiaal (in Dutch), Royal Decree of 25 January 2001 on temporary or mobile construction sites, Justel (in French)
03
Where do you find the fire class of a product?
In the declaration of performance, if reaction to fire is one of the essential characteristics. The declaration gives the performance for each essential characteristic, in levels, classes or a description (Article 6(3) of Regulation (EU) No 305/2011).
The reaction to fire of a construction product is classified as A1, A2, B, C, D, E or F (Delegated Regulation (EU) 2016/364). Some classes also carry a class for smoke production (s1, s2 or s3) and for flaming droplets (d0, d1 or d2).
For roofs and roof coverings there is also a classification for fire from outside, with classes such as BROOF(t1) (Decision 2001/671/EC). Each Member State chooses which tests and classes a roof must meet (Annex to that decision).
Sources: Regulation (EU) No 305/2011 (Construction Products Regulation), EUR-Lex, Delegated Regulation (EU) 2016/364 (reaction to fire of construction products), EUR-Lex, Decision 2001/671/EC (external fire performance of roofs), EUR-Lex
04
What does the EPB ask for a flat roof in Flanders?
In Flanders, the EPB rules apply to a building that is heated or cooled, when you apply for an environmental permit for urban development work or make a notification (melding).
The U-value requirements only apply to new, renewed, converted and re-insulated building parts. For a roof, the maximum U-value is 0.24 W/m²K, for applications from 1 January 2018.
The reporter draws up the EPB declaration (EPB-aangifte). It describes how the project was actually built. For the lambda value of an insulation material, the reporter looks up the product used in the EPB product database (EPB-productgegevensdatabank). If the value is unknown or uncertain, the reporter uses a default value.
So give the reporter the exact product name and the thickness of each insulation layer. The reporter works out the thermal resistance of a layer from that thickness and the lambda value.
Sources: Flanders, EPB-pedia: EPB-plicht (in Dutch), Flanders, EPB-pedia: U- en R-waarde (in Dutch), Flanders, EPB-pedia: U-waarden per aanvraagjaar (in Dutch), Flanders, EPB-pedia: EPB-aangifte (in Dutch), Flanders, EPB-pedia: de warmtegeleidbaarheid van een materiaal (in Dutch), Flanders, EPB-pedia: U-waarde van opake scheidingsconstructies (in Dutch)
05
What goes into the post-intervention file?
The post-intervention file (postinterventiedossier, PID) is mandatory on the temporary or mobile construction sites of the Royal Decree of 25 January 2001: with two or more contractors, and also with one contractor (Article 34).
The PID contains at least the identification of the materials used, and the plans that match how the works were actually carried out (Annex I, Part C).
If two or more contractors work on the site, at the same time or one after the other, the coordinator opens the PID, keeps it up to date and adds to it (Articles 4sexies and 11). If only one contractor works on the site, the client draws up the PID, or someone the client appoints (Article 43).
Source: Royal Decree of 25 January 2001 on temporary or mobile construction sites, Justel (in French)
06
Declarebase and your flat roof file
Look up a product in Declarebase. The product page shows whether we found the technical data sheet and the declaration of performance at the manufacturer, with a link to the document and the date we last requested the source. The declaration of performance is the basis for the CE marking. If we find an EPD or an ATG, the page shows it too. If we did not find a document, the page says so too.
Paste your material list into the material list check. For each line you see the product and whether the manufacturer's documents are complete. You need a free account for this.
In a project, you put the materials per phase. You export the approved materials as a ZIP for the PID, with the documents of each material. Projects are part of Bureau.
We do not read the content of the documents and do not say whether a product suits your roof. The manufacturer's document is the source.
Sources
- Regulation (EU) No 305/2011 (Construction Products Regulation), EUR-Lex
- Regulation (EU) 2024/3110 (new Construction Products Regulation), EUR-Lex
- FPS Economy: the trading of construction products
- BUtgb-UBAtc: applying for a technical approval (ATG)
- FPS Public Health: environmental product declarations (B-EPD)
- Delegated Regulation (EU) 2016/364 (reaction to fire of construction products), EUR-Lex
- Decision 2001/671/EC (external fire performance of roofs), EUR-Lex
- Flanders, EPB-pedia: EPB-plicht (in Dutch)
- Flanders, EPB-pedia: U- en R-waarde (in Dutch)
- Flanders, EPB-pedia: U-waarden per aanvraagjaar (in Dutch)
- Flanders, EPB-pedia: EPB-aangifte (in Dutch)
- Flanders, EPB-pedia: de warmtegeleidbaarheid van een materiaal (in Dutch)
- Flanders, EPB-pedia: U-waarde van opake scheidingsconstructies (in Dutch)
- Royal Decree of 25 January 2001 on temporary or mobile construction sites, Justel (in French)
Read also
This is a general explanation, not legal or technical advice. The official text is the source.